12v 12ah 30ah 50ah 100ah 130ah 200ah 24v 48v 100ah Lithium Iron Phosphate Lifepo4 Battery

Short Description:

Lead-acid batteries are widely used, but because of their high maintenance costs, short batterylife and great environmental pollution, they are gradually replaced by lithium ion batteries.Lithium iron phosphate battery with the same volume has higher energy density and lighterweight, which is the best alternative to lead acid.


Product Detail

Parameter

FAQ

Certifications

Manufacturer

Product Tags

Description

Lifepo4 battery is boasts of exceptional durability, reliability and long-lasting performance, making it the ideal battery for a wide range of applications. Whether you are looking to power your electric vehicle, solar panels or portable devices, this battery has got you covered.
Lifepo4 batteries are also highly efficient,they can hold more power on a smaller footprint, making them perfect for applications where space is limited.
Additionally, Lifepo4 batteries are environmentally friendly, being free from toxic substances like cadmium, mercury and lead commonly found in traditional batteries. They are also easy to recycle, meaning they help to reduce waste, making them a sustainable choice for those who value eco-friendliness.
So If you're looking for a high-performance and eco-friendly rechargeable battery solution, then Lifepo4 is definitely the way to go!

More Details

48V 100AH Lifepo4 battery1
12V 50AH Lifepo4 battery2

  • Previous:
  • Next:

  • Modol XPD-1212 XPD-3012 XPD-5012 XPD-10012 XPD-13012 XPD-20012 XPD-10024 XPD-10048
    Capacily 12V12Ah 12V30Ah 12V30An 12V100Ah 12V130Ah 12V200Ah 24V100Ah 48V100Ah
    Continuous Dischag
    Current
    8A 15A 25A 50A 60A 100A 50A 50A
    Peak Protection Curent 16A 16A 16A 100A 130A 200A 100A 100A
    Working Voltage 10-14.6V 20-29.2V 37.5-54.75V
    Standard Voltage 12.8V 25.6V 48A
    Continucus Work Curent 8A 15A 25A 50A 65A 100A 50A 50A
    Max Chage Voltag 14.6V
    Suggested MoD Model 80%
    Size(mm) 55*99*94 195*133*171 229*139*208 256*165*210 330*172*215 521*238*218 345*190*245 520*267*220
    weight 1.5kg 3.2kg 4.5kg 10kg 13kg 19kg 22kg 33kg
    Humidity 85%
    Cooing Type Natural Cooling
    IP IP67
    Useful Life 8-10 Years

    1. Why is your quotation higher than other suppliers?

    In the Chinese market, many factories sell low-cost inverters that are assembled by small, unlicensed workshops. These factories cut costs by using substandard components. This results in major security risks.

    SOLARWAY is a professional company engaged in R&D, manufacturing, and sales of power inverters. We have been actively involved in the German market for over 10 years, exporting around 50,000 to 100,000 power inverters each year to Germany and its neighboring markets. Our product quality is deserving of your trust!

    2. How many categories do your power inverters have according to the output waveform?

    Type 1: Our NM and NS series Modified Sine Wave inverters use PWM (Pulse Width Modulation) to generate a modified sine wave. Thanks to the use of intelligent, dedicated circuits and high-power field-effect transistors, these inverters significantly reduce power loss and improve the soft-start function, ensuring greater reliability. While this type of power inverter can meet the needs of most electrical equipment when power quality is not highly demanding, it still experiences around 20% harmonic distortion when running sophisticated equipment. The power inverter can also cause high-frequency interference to radio communications equipment. However, this type of power inverter is efficient, produces low noise, is moderately priced, and is therefore a mainstream product on the market.

    Type 2: Our NP, FS, and NK series Pure Sine Wave inverters adopt an isolated coupling circuit design, offering high efficiency and stable output waveforms. With high-frequency technology, these power inverters are compact and suitable for a wide range of loads. They can be connected to common electrical devices and inductive loads (such as refrigerators and electric drills) without causing any interference (e.g., buzzing or TV noise). The output of a pure sine wave power inverter is identical to the grid power we use daily—or even better—since it does not produce the electromagnetic pollution associated with grid-tied power.

    3. What are resistive load appliances?

    Appliances such as mobile phones, computers, LCD TVs, incandescent lights, electric fans, video broadcasters, small printers, electric mahjong machines, and rice cookers are considered resistive loads. Our modified sine wave inverters can successfully power these devices.

    4. What are inductive load appliances?

    Inductive load appliances are devices that rely on electromagnetic induction, such as motors, compressors, relays, fluorescent lamps, electric stoves, refrigerators, air conditioners, energy-saving lamps, and pumps. These appliances typically require 3 to 7 times their rated power during startup. As a result, only a pure sine wave inverter is suitable for powering them.

    5. How to choose a suitable inverter?

    If your load consists of resistive appliances, such as light bulbs, you can choose a modified sine wave inverter. However, for inductive and capacitive loads, we recommend using a pure sine wave inverter. Examples of such loads include fans, precision instruments, air conditioners, refrigerators, coffee machines, and computers. While a modified sine wave inverter may start some inductive loads, it can shorten its lifespan because inductive and capacitive loads require high-quality power for optimal performance.

    6. How do I choose the size of the inverter?

    Different types of loads require different amounts of power. To determine the size of the inverter, you should check the power ratings of your loads.

    • Resistive loads: Choose an inverter with the same power rating as the load.
    • Capacitive loads: Choose an inverter with 2 to 5 times the power rating of the load.
    • Inductive loads: Choose an inverter with 4 to 7 times the power rating of the load.

    7. How should the battery and inverter be connected?

    It is generally recommended that the cables connecting the battery terminals to the inverter be as short as possible. For standard cables, the length should be no more than 0.5 meters, and the polarity should match between the battery and the inverter.

    If you need to increase the distance between the battery and the inverter, please contact us for assistance. We can calculate the appropriate cable size and length.

    Keep in mind that longer cable connections can cause voltage loss, meaning the inverter voltage may be significantly lower than the battery terminal voltage, leading to an undervoltage alarm on the inverter.

    8. How do you calculate the load and working hours required to configure the battery size?

    We typically use the following formula for calculation, though it may not be 100% accurate due to factors like the condition of the battery. Older batteries may have some loss, so this should be considered a reference value:

    Work hours (H) = (Battery capacity (AH)*Battery voltage (V0.8)/ Load power (W)

    证书

    工厂更新微信图片_20250107110031 微信图片_20250107110035 微信图片_20250107110040

    Write your message here and send it to us